Skip to content

layout-reviewer

Left: a grey atrium seen from eye height with labelled floor patches and an orange capsule figure. Right: the same building cut open from above

A B.2 greybox of a mall from eye height and as a cutaway. Flat labelled patches mark furniture zones. The orange capsule is a person for scale.

The layout-reviewer is the gate for a world's structure. It ranks and scores shell layouts, zoning plans and greybox variants, and signs off the refined greybox.

When it runs

Stage Mode
A.3 shell layouts ranks them; the owner picks
B.1 floor plan ranks the zoning variants
B.2 greybox ranks the variants in 3D from eye height
B.2 pick signs off the refined pick

What you give it

The orchestrator passes:

  1. the WORLD.md path,
  2. the stage: A.3 shell layouts, B.1 floor plan, B.2 greybox, or B.2 pick sign-off,
  3. the candidate files or scene roots with their shot positions,
  4. RANK or JUDGE,
  5. the previous report, on a re-review.

What it returns

  • Ranking: first a judgement of the set (do the variants really diverge?), then a score out of 10 per variant, a rank, and what to graft from the runners-up.
  • Sign-off: a verdict and a score for the refined pick.
  • Its own captures. It shoots the same camera set for every variant, at eye heights of 1.3 m, 0.9 m and 1.6 m.

Verdict and score

  • Rankings return RANKED: every option scored out of 10 with its reasons, best first.
  • If the top two are within one point, it names the question to ask the owner.
  • Sign-off returns SHIP IT, MINOR FIXES or NEEDS WORK. SHIP IT needs no blocker, no should-fix and a score of 8 or more.
  • SHIP IT on the pick means "blueprint approved; C.1 build-out may start". The greybox is not playable and is not walk-tested.
  • A.3 has no SHIP IT loop. The owner's pick is the acceptance.

Main criteria

  1. Archetypes and organisation. Every space is labelled A1 to A5 and sized from its archetype.
  2. Massing. Not a single box. Every overhang visibly supported, nothing floats, every cut ends on a corner.
  3. Program and intimacy gradient. Every must-have is present. Anything the brief calls private is a teleport island.
  4. Circulation. Main paths 2.0 to 2.4 m wide, never below 2.0 m. Private doors 1.0 to 1.2 m, main portals 2.2 to 2.4 m.
  5. Scale and section. At least 2.3 m clear over paths. At most one level change per social zone, with 3 risers or more or a ramp.
  6. Arrival. The planned spawn faces into the space, never a wall within 3 m.
  7. Seating zones. At edges, backs covered. A1 rooms (intimate retreats) at least 25 m from loud rooms, or in an audio zone.
  8. World extent. Cuddle zones under 256 m and occupied space under 512 m from the origin. Teleport islands at least 200 m apart.
  9. Buildability and budget. Sightlines that would put more than 3 M triangles in view are flagged now.
  10. Furniture zones. Every group the program needs has a rough labelled zone, clear of door zones.

Furniture pieces of any kind in a B.1 plan or a B.2 greybox are a finding. A layout that contradicts an owner decision is a blocker.

What it never does

  • Never judges furniture pieces, materials, prop styling, lighting or mood.
  • Never judges dimensions or layout against an image.
  • Never accepts a finding from a camera position no person can occupy.
  • Never judges colliders, the spawn object, stair ramps, teleport doors or clip planes in A.3 or B. Those are built in C.2.
  • Never fixes anything. Review only.

Whose work it judges: world-architect.

Source: agents/layout-reviewer.md.